LiveWire Core 1200 Technical Specifications
Specification
|
Description
|
---|---|
Base
|
OEM PowerEdge R6525 Server
|
Chassis
|
3.5" Chassis with up to 4 Hot Plug Hard Drives
|
Motherboard
|
PowerEdge R6525 Motherboard
|
Processor
|
AMD 7313 3.0GHz,16C/32T (1)
|
Memory
|
64 GB 3200MT/s, Dual Rank (4x16)
|
RAID/Internal Storage Controllers
|
PERC H745 Controller, Front
|
Hard Drive
|
BOSS-S2 controller card + with 2 M.2 240GB (RAID 1)
8TB 7.2K RPM SAS ISE 12Gbps 512e 3.5in Hard Drive (4)
|
Network Adapters
|
2 x 1Gb Onboard LOM
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0
|
Fans
|
Standard Fan x6
|
Power Supply
|
Dual, Hot Plug, Redundant Power Supply (1+1), 800W
|
Power Cords
|
C13 to C14, PDU Style, 12 AMP, 6.5 Feet (2m) Power Cord, North America
|
PCIe Riser
|
Riser Config 1, 1 x 16 FH
|
Embedded Systems Management
|
iDRAC9, Enterprise
|
Quick Sync
|
None
|
Rack Rails
|
ReadyRails Sliding Rails Without Cable Management Arm
|
PSU Specifications:
PSU
Class
Heat Dissipation (Maximum)
Frequency
Voltage
Current
|
8OO W Mixed Mode
Platinum
3000 BTU/hr
50/60 Hz
100–240 V AC, autoranging
9.2 - 4.7 A
|
Temperature Specifications A2:
|
|
Allowable continuous operations
|
|
Temperature ranges for altitudes <= 900 m (<= 2953 ft)
|
10–35°C (50–95°F) with no direct sunlight on the equipment
|
Humidity percent ranges (non-condensing at all times)
|
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
|
Operational altitude de-rating
|
Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
|
Temperature Specifications A3:
|
|
Allowable continuous operations
|
|
Temperature ranges for altitudes <= 900 m (<= 2953 ft)
|
5–40°C (41–104°F) with no direct sunlight on the equipment
|
Humidity percent range (non-condensing at all times)
|
8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
|
Operational altitude de-rating
|
Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft)
|
Temperature Specifications A4:
|
|
Allowable continuous operations
|
|
Temperature range for altitudes <= 900 m (<= 2953 ft)
|
5–45°C (41–113°F) with no direct sunlight on the equipment
|
Humidity percent range (non-condensing at all times)
|
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
|
Operational altitude de-rating
|
Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft)
|
Temperature Specifications Shared Requirements Across All Categore:
|
|
Allowable continuous operations
|
|
Maximum temperature gradient (applies to both operation and non-operation)
|
20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape hardware
NOTE * - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change. |
Non-operational temperature limits
|
-40 to 65°C (-40 to 149°F)
|
Non-operational humidity limits
|
5% to 95% RH with 27°C (80.6°F) maximum dew point
|
Maximum non-operational altitude
|
12,000 meters (39,370 feet)
|
Maximum operational altitude
|
3,048 meters (10,000 feet)
|
Maximum Vibration Specifications:
|
|
Operating
|
0.21 Grms at 5 Hz to 500 Hz (all operation orientations)
|
Storage
|
1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
|
Maximum Shock Pulse Specifications:
|
|
Operating
|
Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms.
|
Storage
|
Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.
|